PACET’S PROFAN KITS & FMS ASSEMBLIES

A further development of the Thinline & HighProfile range, where maximum performance is required and there is sufficient space for the bigger motor, with dedicated Pull or Blow blades.   These kits have proved very popular particularly with competition customers or those requiring the very best performance.   Either supplied as Fan/Motor/Shroud (FMS) assemblies or as complete kits. The FMS assemblies are available for those who wish to make up their own assembly or replace the existing unit. Delete the prefix K from the part number when ordering the Profan FMS Assembly only.

Water resistant motors can be submerged for 3 to 4 hours are available on Profan models only - add /WR to part number when ordering.   WR motors add 10mm to H measurement.

All components available separately – see Spares Page for details.

 Shroud_drawing.gif (12092 bytes)

 Thinline Profans

 

*

W mm

D mm

P mm

H mm

S mm

CFM **

m³/h **

Amps

KPF0811

8”

214

241

238

89

35

498

846

7.80

KPF0911

9”

243

276

279

89

35

908

1543

8.90

KPF1011

10”

269

301

323

89

35

1090

1852

10.70

KPF1111

11”

295

324

324

89

35

1242

2110

10.90

KPF1211

12”

321

333

335

96

35

1640

2834

12.00

KPF1311

13”

346

353

354

100

35

1980

3364

12.19

KPF1411

14”

367

373

374

100

35

2139

3634

12.29

KPF1611

16”

406

418

418

100

35

2354

3999

14.00

*  Nominal blade size – see W, D, P*, H & S for overall dimensions
** Performance - At 0.15” ( 3.75mm) static pressure is the equivalent of a typical 1.5” (39mm) thick radiator.   Free air figures are always much greater and look more impressive but are not often relevant and therefore not shown here. Performance figures, intended as a guide, are shown for pulling mode, the most reliable.   Blowing performance is unreliable, as it has degrees of spill and wastage and is only used when space is tight.   ‘0’ Amp draw is taken at nominal 12V rating.   Normal test voltage is 13.5V, for 24V amp draw figure a typical reduction of 45% should be applied.

- add P for Pull or B for Blow after part no. e.g. KPF1011P
- add /24 to part number when ordering 24V
- for Twin Kits add /TW to part number, e.g.KPF1011/TW.  See Twin Kits for details

 High Profile Profans

 

*

W mm

D mm

H mm

S mm

CFM **

m³/h **

Amps

KPF107

10”

267

282

96

56

980

1665

9.00

KPF115

11.5”

305

305

105

60

1690

2871

12.09

KPF126

12”

333

356

105

60

2150

3653

13.09

KPF127

12”

318

330

105

56

2360

4009

14.10

 - add P for Pull or B for Blow after part no. e.g. KPF1011P
- add /24 to part number when ordering 24V
- for Twin Kits add /TW to part number, e.g.KPF1011/TW.  See Twin Kits for details

Twin Kits

Twin kits include the same components as single kits, with one thermostat and one override switch.

twinXL.jpeg (20283 bytes)
Where X and L are dependant on fan size and specification

All the kit components are available separately - click here for details

 

Send mail to webmaster with questions or comments about this web site.
Last modified:  05 Jun 2006